Product News

Loop-Powered Pepperl+Fuchs KFD0-TR-Ex1 Pt100 RTD Converter with 2/3-Wire Input, 4-20 mA Output, and Sensor-Break Detection

News November 18, 2026

Simple Pt100 Signal Conversion with Pepperl+Fuchs KFD0-TR-Ex1

Pepperl+Fuchs KFD0-TR-Ex1 is a single-channel RTD converter for intrinsically safe temperature-measurement loops. It accepts a 2- or 3-wire Pt100 sensor from the hazardous area and converts the resistance value into a standard 4-20 mA signal for safe-area control equipment.

Its loop-powered design is especially useful when a project needs reliable temperature signal isolation without adding a separate module power connection. Compact controls on the front also make range selection and field calibration straightforward.


P+F KFD0-TR-EX1_副本


Why KFD0-TR-Ex1 Stands Out

  • One-channel isolated barrier for Pt100 temperature signals

  • Supports 2-wire and 3-wire RTD connections

  • Standard 4-20 mA safe-area output

  • 12-35 V DC loop-powered operation

  • Selectable temperature-linear output from 25 degrees C to 375 degrees C

  • DIP-switch range selection with rotary controls and potentiometers for calibration

  • Sensor-break detection with a defined fault indication

A Practical Fit for Process Temperature Loops

KFD0-TR-Ex1 can be used where a Pt100 sensor measures bearing, vessel, pipe, utility, or process temperature in a hazardous location. The module provides isolation and sends a familiar current signal to a DCS, PLC, recorder, indicator, or alarm system.

Typical users include oil and gas facilities, chemical plants, power stations, water-treatment systems, marine projects, pharmaceutical production, and general process automation. The module is also relevant for shutdown maintenance and replacement of an existing KFD0-TR-Ex1 already documented in the cabinet drawings.

Details Worth Checking Before Replacement

A matching model number is important, but the complete temperature loop should still be reviewed. Confirm:

  • Pt100 standard and 2-wire or 3-wire field connection

  • Required measurement range and output scaling

  • Available loop voltage and receiving-input load

  • Lead resistance, cable condition, and terminal arrangement

  • Hazardous-area classification and applicable certificates

  • Expected system response when sensor breakage drives the output to a fault level

For urgent maintenance, send a clear label photo together with the original DIP-switch and rotary-switch positions. This helps confirm the existing configuration before the replacement module is installed.

Other hot sales models for your reference.

KFD0-CC-Ex1, KFD0-CS-Ex1.50P, KFD0-CS-Ex2.50P, KFD0-TT-Ex1, KFD2-GUT-Ex1.D, KFD2-UT2-Ex1, KFD2-UT2-Ex2, KFU8-GUT-Ex1.D, KFD2-STC4-Ex1, KFD2-STC4-Ex2, KFD2-STC5-Ex1, KFD2-STC5-Ex2, KCD2-STC-Ex1, KCD2-STC-Ex1.ES, KFD2-VR2-Ex1.50M, and KFD2-VR4-Ex1.26.

Contact Sunup-MTL with the full model number, quantity, destination, and required delivery date for KFD0-TR-Ex1 availability, quotation, export documents, and international shipping support.