Dual-Output Pepperl+Fuchs KFD2-STC4-Ex1.2O SMART Transmitter Power Supply for HART Loops, DCS Inputs, and Signal Splitting
Pepperl+Fuchs KFD2-STC4-Ex1.2O Dual-Output SMART Transmitter Power Supply for HART Measurement Loops and Redundant Control Inputs
When one hazardous-area transmitter signal must be delivered to two separate safe-area destinations, Pepperl+Fuchs KFD2-STC4-Ex1.2O provides a compact and carefully defined signal-splitting solution. It combines transmitter power, intrinsic-safety separation, SMART communication, and two isolated current outputs in a single K-System module.
One Measurement, Two Independent Outputs
KFD2-STC4-Ex1.2O accepts a compatible 2-wire or 3-wire SMART transmitter, or a 2-wire SMART current source. The analogue input is reproduced as two isolated 0/4-20 mA outputs. This can allow the same field measurement to serve a process control system and an independent safety, monitoring, or recording system without directly linking the receiving circuits.
Communication Stays Available
Supported digital communication is transferred bidirectionally, so compatible HART, BRAIN, or Foxboro signals can remain available for device setup and diagnostics. Integrated test sockets make it easier to connect a communicator during commissioning or service work. Where the loop resistance is insufficient for HART communication, the documented internal 250-ohm resistance can be included through the appropriate terminal connection.
Application Snapshot
| Review point | KFD2-STC4-Ex1.2O consideration |
|---|---|
| Input | SMART transmitter or compatible current source |
| Output arrangement | One input split into two isolated current outputs |
| Supply | 24 V DC with Power Rail compatibility |
| Typical use | Parallel DCS, safety system, recorder, or monitoring inputs |
Replacement Checks That Prevent Mismatches
The complete suffix is essential. KFD2-STC4-Ex1.2O is a splitter model; a single-output STC4 or STC5 module is not an automatic substitute. Confirm both receiving-loop loads, terminal assignments, communication requirements, Power Rail supply, and the applicable functional-safety documentation. If the module is being replaced during a shutdown, photograph the existing label and wiring before removal.
For quotation, provide the exact model KFD2-STC4-Ex1.2O, required quantity, delivery destination, and requested delivery date. This information helps distinguish the correct splitter from similar-looking transmitter power supplies and reduces unnecessary technical clarification.
Other hot sales models for your reference.
KFD2-STC4-Ex1, KFD2-STC4-Ex2, KFD2-STC5-Ex1, KFD2-STC5-Ex1.2O, KFD2-STC5-Ex2, KCD2-STC-Ex1, KCD2-STC-Ex1.ES, KFD2-UFC-Ex1.D, KFD2-UT2-Ex1, KFD2-SR2-Ex1.W, KFD2-SR-Ex1.4S.LK, KFD2-ST3-Ex2, KFD2-EB2, KFU8-UFC-Ex1.D, and KFU8-GUT-Ex1.D.
Latest News
-
Non-Contact Pepperl+Fuchs UB500-18GM75-I-V15 Ultrasonic Sensor with 4-20 mA Output for Distance, Position, and Level Measurement…
November
19, 2026
-
Compact Pepperl+Fuchs NJ2-12GM-N NAMUR Inductive Proximity Sensor for Hazardous-Area Valve Position and Machine Detection…
November
19, 2026
-
Dual-Output Pepperl+Fuchs KFD2-STC4-Ex1.2O SMART Transmitter Power Supply for HART Loops, DCS Inputs, and Signal Splitting…
November
19, 2026
